Home > Products > Cochleas > Apparatus stupra > Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)
Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)
  • Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)
  • Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)
  • Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)
  • Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)

Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468)

Subsequens praecisionem et firmitatem cum Dimensionibus Capitis pro Slotted Pan Capitis Cochleas, occurrens ASME B 18.6.3 - 2013 signa. Specimen constructionis, supellectilis collectae, et plura, his cochleis constanti tradenda perficiendi ac facilitatis usui.

Model:ASME B 18.6.3

Mitte Inquisitionem

depictio producti

Subtilitas Engineering:Dimensiones capitis pro slotted Pan Capitis Cochleas, de quibus in ASME B 18.6.3 - 2013, signa exigendis pro dimensionibus et agendis curabit. Obsequium cum ASTM F837 et F468, hae cochleae fidem in variis applicationibus spondent.

Pan Caput Design:Patella slotted design caput caput oblongum superficie rotundo praebet, permittit facilem institutionem et remotionem utens ense torto vertitorio. Hoc consilium praebet metam uisum appellandi, servato functionality.

Variae applicationes:Dimensiones Capitis pro Slotted Pan Capitis Cochleae sunt versatiles et aptae variis industriis, inclusis constructione, supellectili, conventus et applicationes generales ligaturae. Eorum certa persecutio et usus facilior eos doctorum praeferendas electiones faciunt.

Summus Quality Materials:Cochleae hae cochleae praestantem durabilitatem et resistentiam ad corrosionem exhibent, dum diuturnum firmitatem in ambitibus postulandis obtinent.




Post Location
d
0000# 000# 00# 0# 1# 2# 3# 4# 5# 6# 7# 8# 10# 12#
d Nominal Size
PP
dk max
min
k max
min
n max
min
t max
min
0.0210 0.0340 0.0470 0.0600 0.0730 0.0860 0.0990 0.1120 0.1250 0.1380 0.1510 0.1640 0.1900 0.2160
160 120 90/96 80 64.0 56.0 48.0 40.0 40.0 32.0 / 32.0 24.0 24.0
0.042 0.066 0.090 0.116 0.142 0.167 0.193 0.219 0.245 0.270 0.296 0.322 0.373 0.425
0.036 0.060 0.082 0.104 0.130 0.155 0.180 0.205 0.231 0.256 0.281 0.306 0.357 0.407
0.016 0.023 0.032 0.039 0.046 0.053 0.060 0.068 0.075 0.082 0.089 0.096 0.110 0.125
0.010 0.017 0.025 0.031 0.038 0.045 0.051 0.058 0.065 0.072 0.079 0.085 0.099 0.112
0.008 0.012 0.017 0.023 0.026 0.031 0.035 0.039 0.043 0.048 0.048 0.054 0.060 0.067
0.004 0.008 0.010 0.016 0.019 0.023 0.027 0.031 0.035 0.039 0.039 0.045 0.050 0.056
0.008 0.012 0.016 0.022 0.027 0.031 0.036 0.040 0.045 0.050 0.054 0.058 0.068 0.077
0.004 0.008 0.010 0.014 0.018 0.022 0.026 0.030 0.034 0.037 0.041 0.045 0.053 0.061
Post Location
d
14# 1/4 16# 18# 5/16 20# 24# 3/8 7/16 1/2 9/16 5/8 3/4
d Nominal Size
PP
dk max
min
k max
min
n max
min
t max
min
0.2420 0.2500 0.2680 0.2940 0.3125 0.3200 0.3720 0.3750 0.4375 0.5000 0.5625 0.6250 0.7500
/ 20.0 / / 18.0 / / 16.0 14.0 13.0 12.0 11.0 10.0
0.476 0.492 0.528 0.579 0.615 0.631 0.734 0.740 0.863 0.987 1.041 1.172 1.435
0.457 0.473 0.508 0.558 0.594 0.608 0.709 0.716 0.837 0.958 1.000 1.125 1.375
0.139 0.144 0.153 0.168 0.178 0.182 0.211 0.212 0.247 0.281 0.315 0.350 0.419
0.126 0.130 0.139 0.153 0.162 0.166 0.193 0.195 0.228 0.260 0.293 0.325 0.390
0.075 0.075 0.075 0.084 0.084 0.084 0.094 0.094 0.094 0.106 0.118 0.133 0.149
0.064 0.064 0.064 0.072 0.072 0.072 0.081 0.081 0.081 0.091 0.102 0.116 0.131
0.085 0.087 0.093 0.100 0.106 0.108 0.123 0.124 0.142 0.161 0.179 0.197 0.234
0.068 0.070 0.074 0.080 0.085 0.087 0.100 0.100 0.116 0.131 0.146 0.162 0.192
, 7#, 14#, 16#, 18#, 20#, 24# sunt pro cochleis tantum pulsatis.
④,0000#, 000#, 00#, 9/16, 5/8, 3/4 sunt machinarum cochlearum tantum.
, Diameter corporis in cochleis machinis habens capita quam stringere non minus erit quam Classis 2A filo diametro picis minimi nec major quam in stamine majoris fundamentalis diametri.
, Machina stupra Longitudo Thread
1) Amplitudo No.5 et minor.
Cochleae nominales longitudinum aequales tribus diametris et breviores stamina plenaria usque ad unam picem (filam) extendentes.
superficies capitis ferens, vel propius, si res patitur. Nominales longi- tudines majores quam tres diametri, usque ad 1-1/8 inter se
stamina plena-forma usque ad intra duarum vocum (stamina) ferentium superficiei capitis, vel propius, si palam valet. Cochleas longioris
longi- tudines nominales, nisi aliud specificatur, minimum 1 in filo plenae formae habebunt.
2) Amplitudo No.6 et minor.
Cochleae nominales longitudinum aequales tribus diametris et breviores stamina plenaria usque ad unam picem (filam) extendentes.
superficies capitis ferens, vel propius, si res patitur. Nominales longitudinum majores quam tres diametri, usque ad 2 in
stamina plena-forma usque ad intra duarum vocum (stamina) ferentium superficiei capitis, vel propius, si palam valet. Cochleas longioris
longi- tudines nominales habeant minimum longitudinis stamina plenae formae 1.5 in., nisi aliud datum est.


Hot Tags: Caput Dimensiones pro Slotted Pan Caput Cochleas [Tabula 17] (ASTM F837, F468), Sinarum, Manufacturers, Suppliers, Factory, Lupum, Mos, Qualitas

Related Categoria

Mitte Inquisitionem

Libenter placet, ut inquisitionem tuam in forma infra exhibeas. Respondebimus tibi in 24 horis.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept